Rockwell Automation 1788 NetLinx Media Checker Users Manual User Manual
Page 44

44
Specifications
1788-UM002A-US-P – April 2000
Power
Two AA size 1.5 V alkaline batteries
Battery type: ANSI/NEDA-15A or IEC-LR6
Low battery indicated on the display
Typical battery life: 50 hours
Timed power-off function (Battery Save feature)
Dimensions
18.4 cm x 9.8 cm x 4.6 cm
(7.25 in x 3.875 in x 1.8 in)
Weight
354.4 g (12.5 oz)
Environmental Conditions
Temperature
Non-operating (storage):
-20
°
C to +60
°
C
Operating:
0
°
C to +45
°
C
Operating Humidity
10
°
C to 30
°
C: 95 %
±
5 % RH (without condensation)
30
°
C to 40
°
C: 75 %
±
5 % RH (without condensation)
40
°
C to 45
°
C: 45 %
±
5 % RH (without condensation)
Altitude
Non-operating:
0 km to 12 km (40,000 ft)
Operating:
0 km to 4.57 km (15,000 ft)
Electromagnetic Compatibility
Meets FCC part 15-b
Meets EN 50081-1: 1993, EN 50082-1; 1995
Meets AS/NZS 2064
N223
Safety
EN60950 2nd edition, 1,2,3,4 Low Voltage
Directive
C22.2 No. 950 2nd edition (1996)
Display
LCD (2 lines of 16 characters) with backlight
Controls
Four-position rotary switch and 5 tactile-feedback
momentary switches
Warranty
One year from date of purchase
Calibration Period
Two years from manufacturing date