Configure the 1769-ASCII Module as a Generic Module

Appendix A

7. Create your program using these tags.

Name

Type

Value

Controller-scoped Tags

InData

STRING

Empty (Len = 0)

OutData

STRING

Empty (Len = 0)

NewInput

BOOL

0

Program-scoped Tags

CrLf

STRING

A two-character string of $R$L

NewRx

INT

0

NumInts

INT

0

OldRx

INT

0

LenIn

Alias to ASCII module’s I:Data[7]

LenOut

Alias to ASCII module’s O:Data[7]

TxOut0

Alias to ASCII module’s O:Data[0]

TxRxIn0

Alias to ASCII module’s I:Data[0]