18 InView Marquee Message Display
Publication 2706-IN016D-EN-P - February 2009
Additional Information
For additional information on communication port wiring and display
configuration, refer to the InView Marquee Message Display User Manual,
pub
.
Input Current Requirements for 2706-P92C and 2706-P94C
Line Voltage
(VAC)
Frequency (Hz)
100% Display
Load (Amp)
50% Display Load
(Amp)
25% Display Load
(Amp)
100 - P92C
50/60
3.6
2.1
1.3
100 - P94C
50/60
7.1
3.9
2.3
120 - P92C
50/60
2.9
1.7
1.0
120 - P94C
50/60
5.8
3.2
1.9
240 - P92C
50/60
1.4
0.9
0.6
240 - P94C
50/60
2.8
1.6
1.0
Display
Load
100%
Condition - All display pixels are lit in amber
Usage - Highly unlikely, use this value for sizing input power circuit
50%
Condition - 50% of the display lit in amber (screen full of 32 pixel amber ‘B’s)
Usage - Unlikely, not a typical display condition, may be seen with use of bitmaps
25%
Condition - Mixture of red, green and amber characters and spaces
Usage - Typical display load for most message types