Connect the 2706-p92c and 2706-p94c displays – Rockwell Automation 2706-P92C_P94C InView Message Display User Manual

Page 8

Advertising
background image

8 InView Marquee Message Display

Publication 2706-IN016D-EN-P - February 2009

Connect the 2706-P92C and 2706-P94C Displays

1. Open the front of the sign case by turning the half-turn latches to the left

with a large screwdriver. (On the 2706-P92C, there are 3 half-turn latches; on
the 2706-P94C there are 5.) Carefully let the front of the case drop forward.

2. Feed electrical cable through 1/2” water-tight conduit, the outside end of the

connector (supplied), the electrical opening in the sign case, and then
through the inside end of the connector. Screw the inside and outside ends
of the connector together until water-tight.

WARNING

HAZARDOUS VOLTAGE

Contact with high voltage may cause death or serious injury. Always disconnect
power to sign prior to servicing.

Maintain Separation of circuits. Route the incoming power directly to the power
connection terminal block.

Do not run the power wiring over the logic board or optional Legacy Communication
board.

TIP

Use either of the two holes nearest the power connection terminal block.

Half-turn Latches on an 2706-P94C Sign

Front View, closed

Front View, open

Power Connection
Terminal Block

Electrical
Opening

Communication
Opening

Advertising