Mount the terminal in a panel, Panel cutout dimensions – Rockwell Automation 2711PC-T10C4D1 PanelView Plus Terminals and Display Modules User Manual

Page 11

Advertising
background image

PanelView Plus 700 to 1500 and PanelView Plus Compact 1000 Terminals and Display Modules 11

Publication 2711P-IN001I-EN-P - November 2009

Panel Cutout Dimensions

Use the full size template shipped with your terminal to mark the cutout dimensions.

Mount the Terminal in a Panel

Mounting clips secure the terminal to the panel. The number of clips you use

(4, 6, or 8) varies by terminal type.

Follow these steps to mount the terminal in a panel.

1. Cut an opening in the panel by using the panel cutout shipped with the terminal.

2. Make sure the terminal sealing gasket is properly positioned on the terminal.

Terminal Type

Height, mm (in.)

Width, mm (in.)

700 Keypad or Keypad and Touch

167 (6.57)

264 (10.39)

700 Touch

154 (6.08)

220 (8.67)

1000 Keypad or Keypad and Touch

224 (8.8)

375 (14.75)

1000 Touch

224 (8.8)

305 (12.00)

1250 Keypad or Keypad and Touch

257 (10.11)

390 (15.35)

1250 Touch

257 (10.11)

338 (13.29)

1500 Keypad or Keypad and Touch

305 (12.00)

419 (16.50)

1500 Touch

305 (12.00)

391 (15.40)

ATTENTION

Disconnect all electrical power from the panel before making the panel cutout.

Make sure the area around the panel cutout is clear.

Take precautions so metal cuttings do not enter any components already installed in
the panel.

Failure to follow these instructions may result in personal injury or damage to panel
components.