10 Industrial Monitors

Publication 6186M-IN001L-EN-P - July 2008

Mounting Guidelines

Observe these guidelines when installing the monitor in a panel.

Confirm that there is adequate space behind the panel.

Allow a minimum of 51 mm (2.0 in.) around the back, sides, and bottom,

and 77 mm (3.0 in.) on the top for ventilation.

A cabinet with a minimum depth of 74 mm (2.9 in.) is sufficient.

Cut supporting panels to specifications before installation. Take precautions
so metal cuttings do not enter components already installed in the panel.

Supporting panels must be at least 14 gauge to be sure of proper sealing
against water and dust and to provide proper support. The mounting
hardware supplied accommodates panels up to 6.0 mm (0.236 in.) thick.

Panel Cutout Dimensions

The following table lists the panel cutout dimensions for each monitor. Use the
full-size template shipped with each monitor to mark the cutout dimensions.

ATTENTION

Failure to follow these guidelines may result in personal injury or damage to
the panel components.

Monitor Model

Cutout Dimensions, Approx. (H x W)

1200M

238.0 x 318.0 mm (9.37 x 12.51 in.)

1500M

285.6 x 386.6 mm (11.24 x 15.22 in.)

1700M

329.5 x 424.0 mm (12.97 x 16.69 in.)

1900M

363.5 x 449.6 mm (14.31 x 17.70 in.)