Connect dc power – Rockwell Automation 6186-Mxxx Industrial Monitors Installation Instructions User Manual

Page 23

Advertising
background image

Industrial Monitors 23

Publication 6186M-IN001L-EN-P - July 2008

Connect DC Power

The monitors connect to a DC power source using a DC input terminal block.

Follow these steps to connect power to the monitor.

1. Turn off the main power switch or breaker.

2. Route the power wires from your DC power supply and connect the leads to

the DC input terminal block on the monitor.

The monitors accept a 9…36V DC input power-supply connection.

3. Tighten the screw terminals to provide a good connection.

4. Secure the terminal block connector to the unit by using the two side

screws.

5. Restore DC power.

ATTENTION

Connect the product to earth ground using a 1.31 mm

2

(16 AWG) or larger

external wire. The ground wire should have green insulation with a yellow
stripe for easy identification.