Environment, Communications, Certifications – Rockwell Automation 2705 RediSTATION Operator Interface User Manual User Manual
Page 44: Environment communications certifications

Publication 2705-UM001A-EN-P
A-2 Specifications
Environment
Communications
Certifications
Ambient Temperature
Operating Temperature
0 to 55
°
C (32 to 131
°
F)
Storage
-40 to 85
°
C (-40 to 185
°
F)
Relative Humidity (non-condensing)
5 to 95%
50% max at 40
°
C (104
°
F)
Shock and Vibration
Shock (operating)
30G
Impulse Shock (non-operating)
50G
Vibration (operating)
2.5G at 58 to 2000 Hz
5 to 57 Hz 0.38mm displacement
(peak-to-peak)
Vibration (non-operating)
5.0G at 58 to 2000 Hz
5 to 57 Hz 0.76mm displacement
(peak-to-peak)
DeviceNet
Data Rates
125K, 250K, 500K BPS
Maximum Distance
500 meters (1600 feet) @125K
200 meters (600 feet) @250K
100 meters (300 feet) @500K
LED Indicator (Mod/Net Status)
Operating Status (Green/Red)
2705-T3DN1B42A (conduit entry)
UL Listed for Hazardous Location A196
Approved for Class I, Groups A, B, C, D,
Division 2, C-UL
2705-T3DN1A42A (sealed connector)
UL Listed A191, C-UL