Programming

Chapter 2

2-17

Speed Detect
The Speed Detect parameter determines the speed at which the Speed
Level Indicator output changes state. If the motor speed is above this
programmed level, the output is Off.

Data Range:

RPM 00000 to 30000

Default Value:

00300

Load Detect
The Load Detect parameter determines the commanded torque level at
which the Load Level Indicator output changes state. If the torque
command exceeds this programmed level, the output is On. The data
defines the torque as a percent of the continuous rated torque of the
specific motor/drive combination and cannot exceed the peak torque
capacity of the motor (1.2 x 30 minute motor rating).

Data Range:

% 000 to 250

Default Value:

% 125