Rockwell Automation 8510 AC Spindle Drive System Programming Manual User Manual
Page 31

Programming
Chapter 2
2-28
Max +Volt In
This parameter requires the user to input the positive command
voltage that is equal to the maximum torque command. When the
Select key is pressed, the control will read the input voltage on Analog
Input #2 and use that as the maximum torque command reference
value. The display will function as a voltmeter to show the voltage
being read on the analog input.
Data Range:
VOLT 00.000 to 10.000
Default Value
10.000
PROGRAM VALUE
This menu allows selection of the steps required to calibrate the analog
input by presetting the display as a normal scrolled variable. Use this
calibration method if the actual command voltages are not available.
Zero Volt In
This parameter requires the user to program the value of the command
voltage that is equal to the zero torque command.
Data Range:
VOLT 0.000 to
±
9.999
Default Value
0.000
Max +Volt In
This parameter requires the user to program the value of the command
voltage that is equal to the maximum torque command.
Data Range:
VOLT 00.000 to 10.000
Default Value
10.000