Remove the drive covers – Rockwell Automation 2099-K7KCB-1 Kinetix 7000 DC-DC Converter and Control Board Kits User Manual
Page 4
 
Publication 2099-IN002B-EN-P — October 2008
4
Kinetix 7000 DC-DC Converter and Control Board Kits
2.
Allow five minutes for the dc bus to completely discharge before 
proceeding. 
3.
Label and remove the fiber-optic (Tx and Rx) cables, and I/O (IOD), 
motor feedback (MF), and auxiliary feedback (AF) connectors from the 
drive. 
4.
Go to Remove the Drive Covers.
Remove the Drive Covers
Depending on the catalog number of your Kinetix 7000 drive, access to the 
control board, dc-dc converter, and fuse varies. 
ATTENTION
This product contains stored energy devices. To avoid 
hazard of electrical shock, verify that all voltage on 
capacitors has been discharged before attempting to 
service, repair, or remove this unit. You should only attempt 
the procedures in this document if you are qualified to do 
so and are familiar with solid-state control equipment and 
the safety procedures in publicatio. 
ATTENTION
This drive contains ESD (electrostatic discharge) sensitive parts 
and assemblies. You are required to follow static control 
precautions when you install, test, service, or repair this 
assembly. If you do not follow ESD control procedures, 
components can be damaged. If you are not familiar with static 
control procedures, refer to Guarding Against Electrostatic 
Damage Service Bulletin, 
r any other
applicable ESD protection handbook.
Cat. No.
Topic
Page
2099-BM06-S, 2099-BM07-S, or 
2099-BM08-S 
Remove 2099-BM06-S, 2099-BM07-S, 
and 2099-BM08-S Covers 
2099-BM09 -S or 2099-BM10-S
Remove 2099-BM09-S and 2099-BM10-S 
Covers 
2099-BM11-S, or 2099-BM12-S