9

Refer to Remove the Drive Covers on page 4 and reverse the order of
steps for your drive module.

8.

Return the drive to operation.

Install the Control Board Kit

Follow these steps to remove and replace the control board.

1.

Label and remove the safe-off (SO), general purpose I/O (GPIO),
general purpose relay (GPR), and ribbon cable connectors from the
control board.

Also, label and remove the fiber-optic (Tx and Rx) connectors, if not
removed earlier.

2.

Remove the six connector stand-offs by using a 3/16 in. thin-walled
socket or nut driver.

3.

Remove the two connector plate screws by using a small Phillips
screwdriver.

IMPORTANT

When replacing the top cover, temporarily remove the
fiber-optic cables from the drive Tx and Rx connectors. This
allows the top cover to seat properly with the chassis.

Kinetix 7000 Drive

(2099-BM07-S is shown)

Ribbon Cable

Connector

Control Board

Screws

Control Board

Connector Plate

Connector Plate

Screws, 2x

Connector Plate

Stand-offs, 2x

Connector Stand-offs, 6x

SO, GPIO, GPR, and

Fiber-optic Connectors

Display Board

IMPORTANT

Thin-walled socket or open-ended wrench is required to
remove the screws due to the clearance between screw
and connector.