Rockwell Automation 1797-IRT8 FLEX Ex Thermocouple/RTD Module User Manual
Page 20

20 FLEX Ex Thermocouple/RTD Input Module
Publication
1797-5.4 - June 2010
Environmental Conditions
Operational Temperature
Storage Temperature
Relative Humidity
Shock
Operating
Nonoperating
Vibration
-20…+70°C (-4…+158°F)
-40…+85°C (-40…+185°F)
5…95% noncondensing
Tested to 15 g peak acceleration, 11(+1) ms pulse width
Tested to 15 g peak acceleration, 11(+1) ms pulse width
Tested 2 g @ 10…500 Hz per IEC68-2-6
Agency Certification
CENELEC
II (1) 2G Ex ib[ia] IIC T4
II (1) D [Ex iaD]
U, C-UL
Class I, Groups A, B, C and D; Class II, Groups E, F and G;
Class III Hazardous Locations
Class I Zone 1 AEx ib[ia] IIC T4,
FM
Intrinsically safe Class I, Div 1, Groups A, B, C, D, T4.
Associated Apparatus with intrinsically safe
Connection Class I, II, III, Div 1, Groups A--G
Intrinsically safe Class I, Zone 1, AEx ib[ia] IIC T4.
INMETRO
BR-Ex ia/ib IIB/IIC T4
IECEx
[Zone 0] Ex ib[ia] IIC T4
[Ex iaD]
Certificate of Conformity
CENELEC
DMT 98 ATEX E 023 X
UL, C-UL
UL, C-UL File Number E197983
FM
FM Certificate Number 3009806
INMETRO
05/UL-BRAE-0015X
IECEx
IECEx BVS 09.0029X