Rockwell Automation 1440-VSE02-01RA XM-122 gSE Vibration Module User Manual
Page 101

Publication GMSI10-UM013D-EN-P - May 2010
Configuration Parameters 91
Shows the measured average DC offset of the
tachometer signal. This value is compared with
Fault High and Fault Low to determine whether
the tachometer is working properly.
The tachometer must be enabled
(Pulses Per Revolution set to 1 or
more).
Speed Value
Shows the measured speed value.
Peak Speed
Shows the greatest measured Speed Value
(positive or negative) since the most recent reset.
Acceleration Measured Value
Show the measured acceleration value. The
acceleration is the rate of change of the Speed
Value.
4–20 mA Output A and B (XM
Serial Configuration Utility only)
Shows the current output value in the range of 4.0 to
20.0 mA.
gSE Status (XM Serial
Configuration Utility only)
States whether a fault condition exists on either
channel. If a fault exists, the gSE overall value may
not be accurate.
Possible status values: No Fault
Fault
gSE Overall
Shows the measured gSE overall value.
Monitor Data Parameters
Parameter Name
Description
Values/Comments
XM Configuration
Utility
EDS File
Xdcr DC Bias
(Transducer
3 Measured
DC Bias