Configuration Parameters 57
Measurement Time
Conventional Mode
The conventional mode will produce measurements for a period of time
according to the following table:
gSE Mode
The gSE mode will produce measurements for a period of time according to
the following table:
Conventional Mode Time
Signal Detection
Sampling Mode
The greater of the two...
RMS
Asynchronous
(Number of Averages) (Number of Lines) /
FMAX
5 x Overall Time Constant
(seconds)
RMS
Synchronous
(Number of Averages) (Number of Lines) /
(FMAX x 100)
5 x Overall Time Constant
(seconds)
True Peak
Asynchronous
(Number of Averages) (Number of Lines)/
FMAX
1 second + 2 / High Pass
Corner Frequency
True Peak
Synchronous
(Number of Averages) (Number of Lines) /
(FMAX x 100)
1 second + 2 / High Pass
Corner Frequency
gSE Mode Time
The greater of...
(Number of Averages) (Number of Lines) /
FMAX
4 seconds