Instances, Instance attributes, Instances instance attributes – Rockwell Automation 1440-VSE02-01RA XM-122 gSE Vibration Module User Manual
Page 185

Publication GMSI10-UM013D-EN-P - May 2010
DeviceNet Objects 175
Instances
There are 6 instances of this object.
Instance Attributes
Table C.64 Vector Measurement Object Instances
Instance
Description
1
Channel 1 1X Vector Measurement
2
Channel 2 1X Vector Measurement
3
Channel 1 2X Vector Measurement
4
Channel 2 2X Vector Measurement
5
Channel 1 3X Vector Measurement
6
Channel 2 3X Vector Measurement
Table C.65 Vector Measurement Object Instance Attributes
Attr ID
Access
Rule
Name Data
Type
Description
Semantics
3
Get
Magnitude
Value
REAL
The measured magnitude
value.
4
Get
Phase Value
REAL
The measured phase
value.
Degrees
Note: Note valid for instances 5
and 6.
5
Get
Status
BOOL
Indicates if a fault or
alarm has occurred.
0 = Operating without alarms of
faults.
1 = Alarm or fault condition
exists. The Value attributes
may not represent the actual
field value.