Determine What You Need

For each Kinetix 2000 drive system, you need to know the drive and motor/actuator catalog numbers to determine the
motor power and feedback cable catalog numbers. Interface cables, connector kits, and a Bulletin 2093 power rail are also
required. Optional equipment includes the 2093 shunt module, slot-filler modules, line interface module, AC line filter,
and others. Example diagrams of the required equipment listed on this page are shown on

page 4

.

Required Drive Modules

Refer to the Kinetix Servo Drives Technical Data Specifications, publication

GMC-TD003

, for detailed descriptions and

specifications for the Kinetix 2000 drive family.

Required Drive Accessories

Refer to the Kinetix Motion Accessories Technical Data, publication

GMC-TD004

, for detailed descriptions and

specifications of these servo drive accessories.

Drive Module

Drive Cat. No.

Converter

Inverter

Slot Usage

Quantity

Integrated axis module (IAM)
200V class

2093-AC05-MP1

3 kW, 9.67 A (three-phase)

3 kW, 6.42 A (single-phase)

0.3 kW, 1.41 A

Single wide

1 for each power rail

2093-AC05-MP2

0.6 kW. 2.83 A

2093-AC05-MP5

0.9 kW, 4.24 A

Axis module (AM)
200V class

2093-AMP1

N/A

0.3 kW, 1.41 A

Up to 7 for each 8-axis
power rail

2093-AMP2

0.6 kW. 2.83 A

2093-AMP5

0.9 kW, 4.24 A

2093-AM01

1.9 kW, 8.48 A

Double wide

Up to 3 for each 8-axis
power rail

2093-AM02

3.0 kW, 13.4 A

Drive Accessory

Description

Cat. No.

2093 power rail

Backplane and mounting fixture for Bulletin 2093 drive modules: available for 1, 2, 3, 4, 5, 7, and
8-axis systems

2093-PRSx

Low-profile connector kits
(required for flying-lead cables)

Motor feedback connections (15-pin male, D-sub)

2090-K2CK-D15M

Motor feedback (15-pin male, D-sub) and I/O (44-pin male, D-sub)

2090-K2CK-COMBO

Backup battery
(required to maintain absolute position reference)

Installs in the Bulletin 2090 low-profile connector kits listed above and applies to drive systems that
include TLY-Axxxx-B rotary motors and TLAR-Axxxxx electric cylinders

2090-DA-BAT2

SERCOS fiber-optic cables
(required as needed)

Plastic, in-cabinet duty

2090-SCEPx-x

Plastic, on-machine duty

2090-SCNPx-x

Plastic, outdoor, and conduit duty

2090-SCVPx-x

Glass, outdoor, and conduit duty

2090-SCVGx-x

Motor power and feedback cables

Refer to the specific drive/motor combination for the motor cables required for your system