6

Rockwell Automation Publication GMC-RM006A-EN-P - September 2011

Kinetix 2000 Drive Systems

In this example, the leader IAM is connected to the follower IAM via the DC common bus. When planning your panel
layout, you must calculate the total bus capacitance of your DC common bus system to make sure that the leader IAM is
sized sufficiently to pre-charge the entire system. Refer to the Kinetix 2000 Servo Drive User Manual, publication

2093-UM001

, when making this calculation.

Kinetix 2000 Input Power Example (DC common bus)

Motor-end cable connector kits, for use when building your own cables, and panel-mounted breakout components are also
available. Refer to the Kinetix Motion Accessories Technical Data, publication

GMC-TD004

, for detailed descriptions and

specifications of servo drive accessories.

IMPORTANT

If total bus capacitance of your system exceeds the leader IAM pre-charge rating, the IAM seven-segment status indicator will
display error code E90 (pre-charge timeout fault) if input power is applied.

To correct this condition, you must remove axis modules from the power rail to decrease the total bus capacitance.

MAIN VAC

Three-phase

Input Power

2094-ALxxS

Line Interface Module

(optional component)

Axis Modules (4)
2093-AMxx

Integrated Axis Module
2093-AC05-MPx

Shunt Module
(optional component)
2093-ASP06

2093-PRF Slot-filler Module
(required to fill any unused slots)

Power Rail
2093-PRSx

Axis Modules (4)
2093-AMxx

Integrated Axis Module

2093-AC05-MPx

Shunt Module
(optional component)
2093-ASP06

Power Rail
2093-PRSx

230V Control Power

DC Common Bus

AC Line Filter

2090-XXLF-TCxxx

(required for CE)

Input

Fusing

2093-PRF Slot-filler Module
(required to fill any unused slots)