Rockwell Automation Publication GMC-RM006A-EN-P - September 2011

Kinetix 2000 Drive Systems

Kinetix 2000 Drives/TL-Series Electric Cylinder Curves (continued)

1000

800

600

400

200

0

Velocity (mm/s)

600

400

0

800

200

2093-AM01 and TLAR-A2xxxF-B2A

Force

(N)

Force
(lb)

225

180

135

89.9

45.0

0

500

300

700

100

Intermittent curve represents

three-phase and single-phase inputs.

1000

800

600

400

200

0

Velocity (mm/s)

600

400

0

800

200

2093-AM01 and TLAR-A2xxxF-B4A (Brake)

Force

(N)

Force
(lb)

225

180

135

89.9

45.0

0

500

300

700

100

Intermittent curve represents

three-phase and single-phase inputs.

2093-AM02 and TLAR-A3xxxE-B2A

Force

(N)

Force
(lb)

Velocity (mm/s)

100

400

300

0

600

500

200

3000

2400

1800

1200

600

0

674

540

405

270

135

0

Intermittent curve represents

three-phase and single-phase inputs.

2093-AM02 and TLAR-A3xxxE-B4A (Brake)

Force

(N)

Force
(lb)

Velocity (mm/s)

100

400

300

0

600

500

200

3000

2400

1800

1200

600

0

674

540

405

270

135

0

Intermittent curve represents

three-phase and single-phase inputs.

2000

1600

1200

800

400

0

450

360

270

180

89.9

0

2093-AM02 and TLAR-A3xxxH-B2A

Force

(N)

Force
(lb)

Velocity (mm/s)

200

800

600

0

1200

1000

400

Intermittent curve represents

three-phase and single-phase inputs.

2000

1600

1200

800

400

0

450

360

270

180

89.9

0

2093-AM02 and TLAR-A3xxxH-B4A (Brake)

Force

(N)

Force
(lb)

Velocity (mm/s)

200

800

600

0

1200

1000

400

Intermittent curve represents

three-phase and single-phase inputs.

= Intermittent operating region