Rockwell Automation 20D PowerFlex 700S and H Fan Inverter Upgrade Kit (Frame 9) User Manual

Page 16

Advertising
background image

16

Rockwell Automation Publication PFLEX-IN015A-EN-P - March 2005

PowerFlex 700S and 700H Fan Inverter Upgrade Kit (Frame 9)

Step 9: Removing AC
Components from the New
Connector Plate
(on DC Input Drives Only)

IMPORTANT

Do not perform this step on drives with AC input. It removes noise mitigation
circuitry, which is important to drives with AC input.

Task

Description
Remove the 6 M4 Pozidrive screws on the front of the connector plate, which secure the cover for the
circuit board containing AC conditioning circuitry.
Proper tightening torque for reassembly is 3 N•m (27 lb•in).
Remove the M4 Pozidrive screw on the back of the connector plate, which secures the cover for the
circuit board containing AC conditioning circuitry.
Proper tightening torque for reassembly is 3 N•m (27 lb•in).
Remove the plate.

Remove the circuit board.

Replace the plate and screws.

A

B

C