Step 13: reassemble the drive – Rockwell Automation 20D PowerFlex 700S and H Fan Inverter Upgrade Kit (Frame 9) User Manual

Page 21

Advertising
background image

Rockwell Automation Publication PFLEX-IN015A-EN-P - March 2005

21

PowerFlex 700S and 700H Fan Inverter Upgrade Kit (Frame 9)

Step 13: Reassemble the
Drive

Assemble the drive in reverse order of disassembly.

When reconnecting internal cables to the power terminal block, remember to
route incoming AC cables through the common mode inductors on the new
EMI Protection Plate.

If the cable for the fan on the new EMI Protection Plate does not reach the
connection point, rotate the fan 180 degrees.

Advertising
This manual is related to the following products: