Functional safety description, Bill of material, Functional safety description bill of material – Rockwell Automation Safety Function: Hinge Switch User Manual

Page 5

Advertising
background image

Safety Function: Hinge Switch

5

Rockwell Automation Publication SAFETY-AT096A-EN-P – November 2013

Functional Safety Description

Door Monitoring Function

When the door is opened, the hinge switch opens its two safety contacts. When the

hinge switch turns off, the Guardmaster dual-input safety relay (GSR DI) responds by

opening its safety contacts (13...14 and 23…24), de-energizing the coils of K1 and

K2. With power removed, hazardous motion coasts to a stop (Stop Category 0).

Hazardous motion cannot be started until the door is closed and the Reset button is

pressed and released.

E-stop Function

The pulsed outputs of the relay (terminals S11 and S21) are run separately through

the two E-stop contacts to the input terminals S12 and S22, respectively. When the

E-stop is pressed, these two circuits are interrupted. The relay responds to this

circuit interruption by opening its safety contacts (13…14 and 23…24), de-energizing

the coils of K1 and K2. With power removed, hazardous motion coasts to a stop

(Stop Category 0). Hazardous motion cannot be started until the E-stop is released

and the Reset button is pressed and released.

Bill of Material

This application uses these products.

Cat. No.

Description

Quantity

800F-1YP8

800F 1-hold enclosure E-stop station, plastic, PG,

twist-to-release 60 mm, non-illuminated, 1 N.O. contact,

2 N.C. contacts

1

440H-E22027

Hinge switch - Ensign 3: contacts: (safety/aux) 2 N.C.

contacts, 1 N.C. contact, BBM preference: actuator

shaft: length 80 mm diameter: 10 mm-solid, conduit

entry: M16 conduit

1

800FM-G611MX10 800F push button – metal, guarded, blue, R, metal latch

mount, 1 N.O. contact, 0 N.C. contacts, standard,

standard pack (quantity 1)

1

400R-D22R2

Guardmaster dual-input safety relay, 2 dual-channel

universal inputs, 1 N.C. contact, solid-state auxiliary

output

1

100S-C09EJ23BC

Modular control system (MCS) 100S-C safety contactor,

9 A, 24V DC (with electrical coil), bifurcated contact

2