PowerFlex® 700S and 700H Frame 13 Replacement Power Structures

13. Pull the rubber grommet, through which the ASIC board and Power

Supply Voltage Feedback board wire bundles are routed, out of the
drive frame and secure the wire bundles in the left-hand enclosure of the
drive.

14. For drives with AC input, disconnect the precharge cable from the

Rectifying modules and the fan control cables, located in the power
structure to the left of the ASIC board.

Rubber grommet and
wire bundles.

Important: Move wire
bundles to left-hand
enclosure.

Fan control cables.
Shown disconnected.

Precharge cables.
Shown disconnected.