Chapter 2: operation, Dip switch settings – AJA LUT-box User Manual

Page 8

Advertising
background image

LUT-box Mini-Converter v2.1r1

www.aja.com

8

Chapter 2: Operation

DIP Switch Settings

Eight DIP switches are located on the bottom of the unit. The default shipping position
for these switches is Off (left). By default, DIP switch configuration is enabled, and
MiniConfig control is disabled.

The DIP switch label identifies the functions of the switch positions. The LUT-box
originally shipped with a label showing Aux 1, 2, and 3 functions. For LUT-box version 2.0
additional 1D LUT functions were added.

Figure 3. LUT-box DIP Switches

ON

OFF

DIP Switches

Version 2.0 Label

Original Label

Table 1. LUT-box DIP Switch Setting Descriptions, version 2.0

SWITCH

FUNCTION

OFF (Left)

ON (Right)

1

Control

Selects Local (DIP), and
blocks MiniConfig control.

Selects Remote (MiniConfig),
and disables DIP switches 2-8.

2

SDI Input
Mode

SDI 1

SDI 1+2 (Dual Link)

3

HDMI mode HDMI

DVI

4

SDI Pass
Through

Apply LUT processing, if
enabled, and any PsF to P
conversion on the SDI output.

Bypass LUT processing, if
enabled, and any PsF to P
conversion on the SDI output.

5

1D LUT
Select

1D LUT Slot A

1D LUT Slot B

6

1D LUT
Enable

Bypass - No 1D LUT
processing is applied

Enable - The selected 1D LUT
processing is applied.

7

3D LUT
Select

3D LUT Slot A

3D LUT Slot B

8

3D LUT
Enable

Bypass - No 3D LUT
processing is applied

Enable - The selected 3D LUT
processing is applied.

Advertising