Chapter 2: operation, Dip switch settings – AJA LUT-box User Manual
Page 8

LUT-box Mini-Converter v2.1r1
www.aja.com
8
Chapter 2: Operation
DIP Switch Settings
Eight DIP switches are located on the bottom of the unit. The default shipping position
for these switches is Off (left). By default, DIP switch configuration is enabled, and
MiniConfig control is disabled.
The DIP switch label identifies the functions of the switch positions. The LUT-box
originally shipped with a label showing Aux 1, 2, and 3 functions. For LUT-box version 2.0
additional 1D LUT functions were added.
Figure 3. LUT-box DIP Switches
ON
OFF
DIP Switches
Version 2.0 Label
Original Label
Table 1. LUT-box DIP Switch Setting Descriptions, version 2.0
SWITCH
FUNCTION
OFF (Left)
ON (Right)
1
Control
Selects Local (DIP), and
blocks MiniConfig control.
Selects Remote (MiniConfig),
and disables DIP switches 2-8.
2
SDI Input
Mode
SDI 1
SDI 1+2 (Dual Link)
3
HDMI mode HDMI
DVI
4
SDI Pass
Through
Apply LUT processing, if
enabled, and any PsF to P
conversion on the SDI output.
Bypass LUT processing, if
enabled, and any PsF to P
conversion on the SDI output.
5
1D LUT
Select
1D LUT Slot A
1D LUT Slot B
6
1D LUT
Enable
Bypass - No 1D LUT
processing is applied
Enable - The selected 1D LUT
processing is applied.
7
3D LUT
Select
3D LUT Slot A
3D LUT Slot B
8
3D LUT
Enable
Bypass - No 3D LUT
processing is applied
Enable - The selected 3D LUT
processing is applied.