8.0 OPERATOR PANEL KEY & INDICATOR FUNCTION DESCRIPTIONS

1.) Pile Feeder Stop Key

Disables the controller outputs

2.) Pile Feeder Start Key

Initiates startup diagnostic and enables controller outputs

3.) Sheet Mode Key

Selects between production mode and single sheet mode

4.) Sheet Start Key

Initiates feeding of sheets by energizing the vacuum solenoid

5.) Diagnostic Key

Initiates the diagnostic program

6.) Reset Key

Initiates a reset function for counters or error functions

7.) Enter Key

Enters data into a function memory

8.) Pile Table Down Key

Initiates the table down function

9.) Pile Table Stop Key

Initiates the table stop function

10.) Pile Table Up Key

Initiates the table up function (key must be held for continuous
table movement)

11.) Batch Set Key

Initiates the batch counter set up and resets the batch counters

12.) Counter Key

Resets the total counter and the batch counters

13.) Parameter Down Key

Decrement various parameters

14.) Parameter Up Key

Increment various parameters

15.) Sheet Gap Key

Initiates the adjustability of the sheet gap

16.) Sheet Count Input

Indicates when the sheet sensor detects a target (sheet)

Indicator

17.) Batch Interrupt Output

Indicates when the feeding is interrupted at the batch point

Indicator

18.) Sheet Feed Solenoid Output

Indicates the output signal to the vacuum solenoid to feed a sheet

Indicator

19.) Pile Table Status Indicator

Indicates when the feed table is in motion

20.) Pile Feeder Ready Indicator

Indicates when Pile Feeder is powered up and ready for use.