Baumfolder Flexifold: Pile Folder (up to 2004) User Manual

Page 21

Advertising
background image

PAGE 21

TP10456-EN

14.0 RESETTING THE TOTAL COUNTER

The following instructions will allow you to reset the Total Counter.
Note: The Batch Counter will also be reset to zero, 0, when the Total Counter is reset.

1. Press the Reset Key, 5, and the Reset Screen

will be displayed.
2. Press the Count Key, 12, and the display will return to the Batch Count Screen with the Batch
Counter and the Total Counter reset to zero, 0.

RESET

15.0 POWER UP FAULT ERROR MESSAGES

When power is applied to the Feeder Controller, a power up routine is automatically initiated. During

this a message

is displayed. During this Power up routine, various aspects of the controller are checked. The Power up routine
can generate error messages depending on the fault detected. The following Error messages table lists the
messages that can be generated and a possible solution to the problem. The errors must be corrected before
the feeder will become operational. If no errors are detected, the “PLEASE WAIT” screen will disappear, and
a message

will appear for a few seconds. Press Pile Feeder Start Key, 2. This will allow the Pile Feeder to go into
production mode and the display will show the main count screen.

PLEASE WAIT

PRESS FEEDER KEY
VER X.XX

ERROR MESSAGE

REMARKS

DOWN LIMIT FAULT

Check down limit switch, wiring to switch, wiring to controller.

UP SAFETY FAULT

Check up safety switch, wiring to switch, wiring to controller.

STOP KEY FAULT

Check wiring to switch, installation of contact block, wiring to
display board

PILE SENSOR FAULT

Check that sensor is not detecting a machine part, wiring of
sensor to connectors, sensors and wiring to controller.

Check that sensor is not detecting a machine part, wiring of
sensor to connectors, sensor and wiring to controller.

SHEET SENSOR FAULT

DOWN SAFETY FAULT Check down safety switch, wiring to switch, wiring to controller