Baumfolder Flexifold: Pile Folder (up to 2004) User Manual

Page 25

Advertising
background image

PAGE 25

TP10456-EN

9. Press the Enter Key, 7, and the operator panel will return to the

screen.

10. Use the Up Arrow Key, 14, until the message

is displayed.

11. Press Enter Key, 7, and the operator panel display will return to the main count screen.

SENSOR TESTS
PRESS ENTER

PRESS ENTER
TO EXIT TESTS

18.0.3 PILE FEEDER OUTPUT TESTS

This group of tests will help to verify the operation of the output circuits contained in the Output Circuit

Test table. Exiting this Diagnostic program can be done at any time by scrolling to the EXIT screen and pressing
the Enter Key, 7.

1. Turn the main Pile Feeder Power Switch on.
2. Press the Pile Feeder Start Key, 2.
3. Press the Diagnostic Key, 5. The message

will be displayed.

DIAGNOSTIC
(Y) ENTER (N) RESET

SHEET COUNT SENSOR

INACTIVE

ACTIVE

Place sheet under sensor

PILE HEIGHT SENSOR

INACTIVE

ACTIVE

Place hand under sensor

DOUBLE SHEET SENSOR

INACTIVE

ACTIVE

Manually trip Double Sheet Detector

DOWN LIMIT SWITCH

INACTIVE

ACTIVE

Manually trip switch

UP SAFETY SWITCH

INACTIVE

ACTIVE

Manually trip switch

DOWN SAFETY SWITCH

INACTIVE

ACTIVE

Manually trip switch

PILE LOAD SENSOR

INACTIVE

ACTIVE

Ensure table or product is breaking
sensor beam. Place hand in
photobeam path.

INHIBIT INPUT
(1st Station required)

ACTIVE

INACTIVE

Start 1st station or disconnect
communication cable from 1st station

NORMAL

STATE

SENSOR ACTIVATION

SENSOR

DESIGNATION

OPERATED

STATE

Slowly rotate 1st station handwheel

HIGH

LOW

ENCODER INPUT
(1st Station required)

Advertising