PAGE 27

TP10456-EN

OUTPUT

REMARKS

3 STOP SOLENOID
TEST

1 FEED WHEEL TEST

The Feed Wheel should turn on when entering this test and turn off
when the arrow keys are used to select another test. If the Feed Wheel
is not rotating, verify the motor wiring and check dc motor control

The Sheet Stop Solenoid should energize when entering this test and
turn off when the arrow keys are used to select another test. If the
Sheet Stop Solenoid does not energize, check solenoid wiring and
voltage (12 Vdc). This solenoid is not installed on all Feeders.

2 FEED SOLENOID
TEST

The Feed Solenoid should energize when entering this test and turn off
when the arrow keys are used to select another test. If the Feed
Solenoid does not energize, check solenoid wiring and voltage (12
Vdc).

18.0.4 PILE FEEDER INDICATOR TESTS

These tests will test the operation of the each indicator on the operator panel. Exiting this Diagnostic

program can be done at any time by scrolling to the EXIT screen and pressing the Enter Key, 7.

1. Turn the main Pile Feeder Power Switch on.
2. Press the Pile Feeder Start Key, 2.
3. Press the Diagnostic Key, 5. The message

will be displayed.

DIAGNOSTIC
(Y) ENTER (N) RESET

4. Press the Enter Key, 7, to enter the diagnostic tests or press the Reset Key, 5, to exit. The message

will be displayed, if Enter Key is pressed.

KEYPAD TESTS
PRESS ENTER

5. Press the Up Arrow Key, 14, until the message

is displayed.

6. Press the Enter Key, 7, to enter the Indicator Test, and the message

will be displayed.

INDICATOR TESTS
PRESS ENTER

BATCH COUNT