Baumfolder Flexifold: Pile Folder (up to 2004) User Manual

Page 22

Advertising
background image

TP10456-EN

PAGE 22

16.0 RUN FAULT ERROR MESSAGES

These error messages may occur during setup or a production run.

ERROR MESSAGE

REMARKS

INHIBIT

1st Station is not running, check wiring to controller board.

DOUBLE SHEET

Remove the double sheet, check sensor, wiring to controller board

17.0 CONTROLLER LED LIST

The following is a list of LEDs and their associated circuit located on the controller.

18.0 DIAGNOSTIC PROGRAM

The diagnostic program contains several routines that will test the operator keypad, test the controller

sensors, test the controller output circuits and test the panel indicators.

D1

Pile Reload Sensor

D2

Table Enable

D6

Direction

D10

Pile Height Sensor

D11

Double Sheet Detector

D13

Table Up Safety Limit Switch

D14

Table Down Safety Limit Switch

D15

Table Down Limit Switch

D18

Feed Enable

D19

Speed

D21

Pump

D23

Motor AC

D35

+12 Vdc Switched

D40

+5 Vdc Logic Power

D42

+12 Vdc Power

LED

DESIGNATION

ASSOCIATED

CIRCUIT

18.0.1 PILE FEEDER KEYPAD SWITCH TESTS

This test will provide a way of checking the operation of the switches on the operator keypad. During

this test, all outputs from the motors, sensors, etc. are turned off. Also, you may exit this diagnostic program at
any time by pressing the Diagnostic Key, 5.