Banner T18 Series User Manual

T18 sensors - dc voltage series, Dimensions, Cabled emitters

Advertising
background image

T18 Sensors - DC Voltage Series

Self-contained, dc-operated sensors

Printed in USA

Jan 2013

P/N 116163 Rev. B

41.5 mm

(1.64")

ø 30.0 mm

(1.18")

Jam Nut

(Supplied)

11.5 mm

(0.45")

M18 x 1

Thread

ø 15 mm

(0.59")

30.0 mm

(1.18")

Green LED

Power Indicator

Yellow LED

Output Indicator

53.7 mm

(2.11")

ø 30.0 mm

(1.18")

Single-turn

Sensitivity (Gain) Control

(D and L Models)

Additional information on this product is immediately available online at

www.bannerengineering.com/116163

View or download additional information, including excess gain curves, beam patterns and accessories.

For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767.

* Standard 2 m (6.5') cable models are listed.

9 m (30') cable: add suffix “W/30” (e.g., T186E W/30).
4-pin Euro-style QD models: add suffix “Q” (e.g., T186EQ). A model with a QD connector requires a mating

cable.

Use polarized models when shiny objects will be sensed.

Sensing Mode

Range

LED

Output Model*

Opposed

20 m (66')

Infrared

950 nm

T186E

NPN

T18SN6R

PNP

T18SP6R

Retro-reflective

with Gain control

2 m (79")†

NPN

T18SN6L

PNP

T18SP6L

P

Polarized Retro-

reflective

Visible

Red

680 nm

NPN

T18SN6LP

PNP

T18SP6LP

Diffuse with Gain

control

500 mm (20")

Infrared

880 nm

NPN

T18SN6D

PNP

T18SP6D

Fixed Field

25 mm (1")

cutoff

NPN

T18SN6FF25

PNP

T18SP6FF25

50 mm (2")

cutoff

NPN

T18SN6FF50

PNP

T18SP6FF50

100 mm (4")

cutoff

NPN

T18SN6FF100

PNP

T18SP6FF100

Dimensions

Cabled Models

QD Models

bn

bu

wh

bk

+

10 - 30V dc

Load
Load

Cabled Emitters

bn
bu

wh

bk

10 - 30V dc

Load

Alarm

+

bn

bu

10-30V dc

+

NPN (Sinking) Outputs

Standard Hookup

10-30V dc

No Connection

bu

bk

bn

wh

+

PNP (Sourcing) Outputs

Standard Hookup

QD Emitters

Alarm Hookup

Alarm Hookup

bu

bn

wh

bk

+

10 - 30V dc

Load
Load

bn

bu

wh

bk

10 - 30V dc

Load

Alarm

+

NOTE: QD hookups are functionally identical.

WARNING . . . Not To Be Used for Personnel Protection

Never use these products for personnel protection. Doing so could lead to serious injury or death. These

devices do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety

applications. A device failure or malfunction can cause either an energized or de-energized output condition.

Consult your current Banner Safety Products catalog for safety products that meet OSHA, ANSI, and IEC

standards for personnel protection.

Advertising