5 troubleshooting ethernet connections, 6 troubleshooting serial connections – Banner PresencePLUS P4 EDGE 1.3 Series User Manual

Page 192

Advertising
background image

• Data bits = 8 (sensor default)
• Parity = None (sensor default)
• Stop Bits = 1 (sensor default)
• Flow Control = None

6. Trigger the sensor.
7. View the results.

8.5 Troubleshooting Ethernet Connections

1. Check the LEDs on teh sensor's RJ-45 connetor.

• No LEDs are ON: the cable may not be the correct type (straight or crossover), or it could be

broken.

• Only the yellow LED is ON: the electrical connection is good, but the sensor device are not

exchanging data.

• Yellow LED is ON and the green LED is ON or flashing: data are being exchanged between the

PC and the sensor.

2. Verify that the Communication tool is configured correctly.

• The connection should be Ethernet socket 1 - 10.
• Verify that you have selected the desired result data in the Tool tab.

3. Check the receiving device setup.

• Check the IP address. The device IP subnet must match the sensor IP subnet.
• Check the Port number: 20000 - 20009 (not 2000).
• Check all firewall and anti-virus software to verify that it is not blocking the sensor's Ethernet

socket.

8.6 Troubleshooting Serial Connections

1. Verify the hardware.

• Check for breaks in the serial cable.
• Use a straight serial cable from the sensor to the PC.

2. Verify that the Communication tool is configured correctly.

• Verify that the desired result data has been checked.

3. Check the receiving device setup.

• Check the receiving device setup.
• Check that the COM port properties on teh receiving device matches the System parameters in

the sensor (baud rate, data bits, parity, stop bits, and flow control).

P/N 000000

Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com

Tel: 763.544.3164

192

7/2009

Communication Tool Setup

Advertising
This manual is related to the following products: