Troubleshooting error messages – Banner PresencePLUS Pro—PRO Camera User Manual
Page 26

01/04
Startup and Troubleshooting
PresencePLUS
®
Pro
Banner Engineering Corp. • Minneapolis, MN USA
www.bannerengineering.com • Tel: 763.544.3164
20
P/N 68368 rev. B
01/04
Camera Select Tab
--------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------
- Change the connection setup as follows:
Ethernet Connection:
a) Select Ethernet (RJ 45) in the pull-down menu.
b) Change the IP address to the address of the controller.
c) Click OK.
Serial Connection:
a) Select PC Serial (DB9) in the pull-down menu.
b) Click OK.
NOTE: A serial connection requires changes to the controller and an established dial-up network. See the
PresencePLUS Pro Serial Connection Procedures document for instructions on setting up a dial-up
network.
7) Create an inspection, configure the discrete I/O, and begin running inspections.
NOTE: Initially, all discrete I/O’s are configured as inputs. If you create an inspection before configuring the
discrete I/O, no outputs will be available in the test tool. For configuration information, refer to the
PresencePLUS Pro Operator’s Guide (P/N 68367), which is included on the CD.
Troubleshooting Error Messages
“Camera not found on IP 192.168.0.1. Do you want to try another IP address?”
1. Check the power. Is the green Power LED ON?
Yes: Go to step 2.
No: Check the power connection. Verify that the power source is 10–30V dc and at least 1.5 amps.
---------------------------------------------------------------------
2. For an Ethernet connection:
a) Is the yellow LED indicator integrated with the RJ-45 port ON?
Yes: Go to step b.
No: Verify that the cable is the correct type. Direct connection to a PC requires a crossover adapter or a
crossover Ethernet cable. Connection to a network requires a straight Ethernet cable.
192 . 168 . 0 . 1
Ethernet (RJ 45)