Troubleshooting table, Camera not connected to controller, Ethernet connection lost – Banner PresencePLUS Pro—PRO Camera User Manual

Page 28: Communications blocked

Advertising
background image

01/04

Startup and Troubleshooting

PresencePLUS

®

Pro

Banner Engineering Corp. • Minneapolis, MN USA

www.bannerengineering.com • Tel: 763.544.3164

22

P/N 68368 rev. B

01/04

“Failed to capture a full-resolution image on the camera. Please try again.”

See the Troubleshooting Table below.

-----------------------------------------

“Failed to capture a full-resolution image.”

See the Troubleshooting Table below.

-------------------------------------

Troubleshooting Table

This table contains solutions to the most common problems in using the PresencePLUS Pro program. For further
assistance, contact Banner.

Problem

Cause / Solution

-

Power light is not ON.

-

Interface cannot connect to controller.

-

No image on monitor.

Controller not getting enough power

-

Verify that the power supply is 10–30V dc with 1.5 amps.

-

Check the connection to the power supply.

-

Verify that the terminal strip is plugged firmly into the controller.

-

No image on PC or monitor.

-

Active indicator LED on camera is OFF.

-

The software seems to be working correctly, but the

image is missing.

Camera not connected to controller

-

Reconnect the camera cable at the camera and the controller. Power

down and back up.

-

Ensure that the controller is receiving triggers. The trigger mode can be

Continuous, External, or Manual.

-

If the connections are secure, call a Banner Applications Engineer; see

Contacting Banner

on page 3.

-

Error message, “Failed to capture a full-resolution

image on the camera. Please try again.”

-

Image is frozen on PC and monitor.

-

Active indicator LED on camera is OFF.

Camera lost connection to controller

-

Reconnect the camera cable at the camera and the controller. Restart

the PresencePLUS Pro software.

-

If the connections are secure, call a Banner Applications Engineer; see

Contacting Banner

on page 3.

-

Image is frozen on PC, but image on monitor

properly updates.

-

Error message, “Failed to capture full-resolution

image.”

-

Indicator lights on controller’s RJ-45 port are OFF.

Ethernet connection lost

-

Reconnect the cable.

-

Check the cable for any breaks, then power down and back up.

-

Replace the cable.

-

Attempt to close and reopen the PresencePLUS Pro software.

-

If still not resolved, call a Banner Applications Engineer; see

Contacting Banner

on page 3.

-

Focus number does not update.

-

QuickStart fails.

-

Errors when saving inspections to the controller.

FTP communications blocked

-

In the

File pull-down menu in Internet Explorer, uncheck the Work

Offline option.