If MULTIPLE is chosen from the drop-down list, then click Edit Selections to select more than
one port.

• Click View Settings to display the configuration of the connection.
• Data can be sent through 11 different communication connections: one connector for the serial

connection, and 10 sockets (1 to 10) through the Ethernet connector.

• The 10 Ethernet sockets are comprised of the Sensor IP address and port number. The table

below lists the default Ethernet socket addresses.

Port

Default IP Address

Socket

20,000

192.168.0.1

1

20,001

192.168.0.1

2

20,002

192.168.0.1

3

20,003

192.168.0.1

4

20,004

192.168.0.1

5

20,005

192.168.0.1

6

20,006

192.168.0.1

7

20,007

192.168.0.1

8

20,008

192.168.0.1

9

20,009

192.168.0.1

10

• The serial port is the RS-232 connector (Pins 1, 9, and 10) on the Sensor. The deafult settings

for the serial port are listed below.

Default Setting

Attribute

115200

Baud Rate

8

Data Bits

None

Parity

1

Stop Bit

None

Flow Control

3. Format the ASCII string of data (in the Format field).

• Choose a Delimiter and Start and End strings.
• Check the Enable Labels box to add the names for data being sent.

Allowable ASCII string options are shown below.

Note: Start and End strings can now accept ASCII Hex values, and the following special
characters: "\r", "\n", "\t".

P/N 000000

Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com

Tel: 763.544.3164

124

7/2009

PresencePLUS Software Tools