Cutmaster 52 – Tweco 52 CutMaster User Manual

Page 37

Advertising
background image

CUTMASTER 52

Manual 0-4961

OPERATION

4T-5

A-02986

Trigger

Trigger Release

7. Bring the torch within transfer distance to the

work. The main arc will transfer to the work,

and the pilot arc will shut OFF.

NOTE

The gas preflow and postflow are a character-

istic of the power supply and not a function

of the torch.

3

4

Art # A-03383

Trigger

2

1

Trigger Release

8. Cut as usual. Simply release the trigger assembly

to stop cutting.

9. Follow normal recommended cutting practices as

provided in the power supply operator's manual.

NOTE

When the shield cup is properly installed,

there is a slight gap between the shield cup

and the torch handle. Gas vents through this

gap as part of normal operation. Do not at-

tempt to force the shield cup to close this gap.

Forcing the shield cup against the torch head

or torch handle can damage components.

Piercing With Hand Torch

1. The torch can be comfortably held in one hand

or steadied with two hands. Position the hand to

press the Trigger on the torch handle. With the

hand torch, the hand may be positioned close to

the torch head for maximum control or near the

back end for maximum heat protection. Choose

the technique that feels most comfortable and

allows good control and movement.

NOTE

The tip should never come in contact with

the workpiece except during drag cutting

operations.

2. Angle the torch slightly to direct blowback

particles away from the torch tip (and operator)

rather than directly back into it until the pierce

is complete.

3. In a portion of the unwanted metal start the

pierce off the cutting line and then continue the

cut onto the line. Hold the torch perpendicular

to the workpiece after the pierce is complete.

4. Hold the torch away from your body.

5. Slide the trigger release toward the back of the

torch handle while simultaneously squeezing the

trigger. The pilot arc will start.

A-02986

Trigger

Trigger Release

6. Bring the torch within transfer distance to the

work. The main arc will transfer to the work,

and the pilot arc will shut OFF.

NOTE

The gas preflow and postflow are a character-

istic of the power supply and not a function

of the torch.
When the shield cup is properly installed,

there is a slight gap between the shield cup

and the torch handle. Gas vents through this

gap as part of normal operation. Do not at-

tempt to force the shield cup to close this gap.

Forcing the shield cup against the torch head

or torch handle can damage components.

Advertising