Cutmaster 52 – Tweco 52 CutMaster User Manual

Page 56

Advertising
background image

CUTMASTER 52

SERVICE

Manual 0-4961

5-6

5.06 Power Supply Basic Parts Replacement

WARNING

Disconnect primary power to the system

before disassembling the torch, leads, or

power supply.

This section describes procedures for basic parts replace-

ment. For more detailed parts replacement procedures,

refer to the Power Supply Service Manual.

A. Cover Removal

1. Remove the upper and lower screws which

secure the cover to the main assembly. Do not

loosen the lower screws inside the cut out slots

in the bottom of the cover.

Upper

Screws

Lower

Screws

Lower

Screws

Art # A-07947

Slots

2. Carefully pull the Cover up and away from the

unit.

B. Cover Installation

1. Reconnect the ground wire, if necessary.

2. Place the cover onto the power supply so that

slots in the bottom edges of the cover engage the

lower screws.

3. Tighten lower screws.

4. Reinstall and tighten the upper screws.

C. Filter Element Assembly Replacement

The Filter Element Assembly is in the rear panel. For

better system performance, the filter element should be

checked per the Maintenance Schedule (Section 5.02),

and either cleaned or replaced.

1. Remove power from the power supply; turn OFF

the gas supply and bleed down the system.

2. Remove the system cover. See "A Cover Re-

moval" in this section.

3. Locate the internal air line and the fitting from

the filter assembly. Number 1 in the following

illustration.

4. Hold a wrench or similar tool against the locking

ring on the filter assembly fitting, then pull on

the hose to release it. (Numbers 2 and 3 in the

following illustration).

Art # A-07989

1

2

3

4

5

6mm

5. Remove the fitting from the filter element as-

sembly by inserting a 6 mm hex wrench into

the internal hex fitting and turning it counter

clock-wise (left). Numbers 4 and 5 in the previous

illustration.

Advertising
This manual is related to the following products: