Cutmaster 52 – Tweco 52 CutMaster User Manual

Page 57

Advertising
background image

CUTMASTER 52

Manual 0-4961

SERVICE

5-7

6. Disconnect the input line from the filter element

assembly.

7. Remove the filter element assembly through the

rear opening.

NOTE

If replacing or cleaning just the filter element

refer to the following illustration for disas-

sembly.

Art # A-07990

Filter Element

8. Install the new or cleaned assembly by reversing these

procedures.

9. Turn ON the air supply and check for leaks before

reinstalling the cover.

Optional Single-Stage Filter Element Replacement

These instructions apply to power supplies where the

optional Single-Stage Filter has been installed.

The Power Supply shuts down automatically when

the Filter Element becomes completely saturated. The

Filter Element can be removed from its housing, dried,

and reused. Allow 24 hours for Element to dry. Refer

to Section 6, Parts List, for replacement filter element

catalog number.

1. Remove power from power supply.

2. Shut OFF air supply and bleed down system

before disassembling Filter to change Filter Ele-

ment.

3. Disconnect gas supply hose.

4. Turn the Filter Housing Cover counter-clockwise

and remove it. The Filter Element is located

inside the Housing.

Art # A-02476

Filter

Element

(Cat. No. 9-7741)

Housing

Cover

Barbed

Fitting

Spring

Assembled Filter

O-ring

(Cat. No. 9-7743)

Optional Single-Stage Filter Element Replacement

5. Remove the Filter Element from the Housing and

set Element aside to dry.

6. Wipe inside of housing clean, then insert the

replacement Filter Element open side first.

7. Replace Housing on Cover.

8. Reattach gas supply.

NOTE

If unit leaks between housing and cover,

inspect the O-ring for cuts or other damage.

Optional Two-Stage Filter Element Replacement

The Two-Stage Air Filter has two Filter Elements. When

the Filter Elements become dirty the Power Supply will

continue to operate but cut quality may become unac-

ceptable. Refer to Section 6, Parts List, for replacement

filter element catalog number.

1. Shut OFF primary input power.

2. Shut OFF air supply and bleed down system.

WARNING

Always turn OFF the air supply and bleed

the system before disassembling the Filter

Assembly as injury could result.

3. Loosen the two bolts on the top of the Filter As-

sembly enough to allow the Filter Elements to

move freely.

4. Note the location and orientation of the old Filter

Elements.

5. Slide out the old Filter Elements.

Advertising