Cutmaster a80 – Tweco A80 CutMaster User Manual

Page 102

Advertising
background image

CUTMASTER A80

SERVICE

Manual 0-4985

5T-2

5T.02 Inspection and Replacement of

Consumable Torch Parts

WARNING

Disconnect primary power to the system before

disassembling the torch or torch leads.

DO NOT touch any internal torch parts while the AC

indicator light of the Power Supply is ON.

Remove the consumable torch parts as follows:

NOTE

The shield cup holds the tip and starter cartridge

in place. Position the torch with the shield cup

facing upward to prevent these parts from falling

out when the cup is removed.

1. Unscrew and remove the shield cup from the torch.

NOTE

Slag built up on the shield cup that cannot be re-

moved may effect the performance of the system.

2. Inspect the cup for damage. Wipe it clean or replace

if damaged.

Shield Cups

3. On torches with a shield cup body and a shield cap or

deflector, ensure that the cap or deflector is threaded

snugly against the shield cup body. In shielded drag

cutting operations (only), there may be an O-ring

between the shield cup body and drag shield cap. Do

not lubricate the O-ring.

4. Remove the tip. Check for excessive wear (indicated

by an elongated or oversized orifice). Clean or replace

the tip if necessary.

Example of Tip Wear

5. Remove the starter cartridge. Check for excessive wear,

plugged gas holes, or discoloration. Check the lower

end fitting for free motion. Replace if necessary.

6. Pull the Electrode straight out of the Torch Head. Check

the face of the electrode for excessive wear. Refer to

the following figure.

Electrode Wear

7

. Reinstall the Electrode by pushing it straight into the

torch head until it clicks.

8

. Reinstall the desired starter cartridge and tip into the

torch head.

9. Hand tighten the shield cup until it is seated on the

torch head. If resistance is felt when installing the cup,

check the threads before proceeding.

This completes the parts replacement procedures.

Advertising