Appendix 7: raw arc voltage, Cutmaster a80 – Tweco A80 CutMaster User Manual

Page 120

Advertising
background image

CUTMASTER A80

APPENDIX

Manual 0-4985

A-10

APPENDIX 7: RAW ARC VOLTAGE

If raw arc voltage is necessary for the torch height control, the customer must supply an 18 AWG (1.0 mm2), single pair, unshielded

cable rated for 300V or greater. All work must be performed following applicable local and national codes.

1. Disconnect the power from the power supply.

2. Remove the screws that attach the power supply cover to the chassis. Remove the cover.

3. Route the cable through the customer supplied strain relief at the rear of the power supply.

4. On the main board use insulated type 1/4-inch ring lug terminal ends to connect to –Vout1 (- polarity) and WORK 1 (+ polar-

ity).

WARNING

The raw arc voltage can exceed 350VDC!!!!

Advertising