5.04 Fault Indicator
At initial power up, two lights will temporarily illuminate for 2-3
seconds to show the version of software used.
To determine the first digit, count the function indicators left
to right, 1 through 5. To determine the second digit count the
pressure indicators, reading from bottom to top, 0 through 7.
In the example below the Temp indicator and 76 psi indicators
are ON indicating the version would be 2.3.
When the
"Fault" indicator is ON or blinking it will be
accompanied by one of the pressure indicator lights de-
pending on what the Fault is. The following table explains
each of those Faults.
Pressure
Indicator
Fault
Max
Over Pressure
90
Internal Error
85
Shorted Torch
80
Consumables Missing
75
Start Error
70
Parts in Place
65
Input Power
Min
Under Pressure
NOTE
Fault explanations are covered in the following
tables.