Cutmaster a80 – Tweco A80 CutMaster User Manual

Page 25

Advertising
background image

CUTMASTER A80

Manual 0-4985

INSTALLATION

3-3

4. If the power cable being used is not the factory - sup-

plied cable, use a three - conductor input power cable

for the voltage desired and strip back the insulation on

the individual wires.

5. Pass the cable being used through the access opening

in the back panel of the power supply. Refer to Section

2 for power cable specifications.

CAUTION

The primary power source and power cable must

conform to local electrical code and the recom-

mended circuit protection and wiring requirements

(refer to table in Section 2).

6. Connect the wires as follows.

• Connect Bus Bar Jumpers on the contactor as

shown in prior illustration and on label in the power

supply.

• Green / Yellow wire to Ground.

7. With a little slack in the wires, tighten the through - hole

protector to secure the power cable.

8. Reinstall the Power Supply cover.

See "B. Cover Installation".

9. Connect the opposite end of individual wires to a

customer supplied plug or main disconnect.

10. Connect the input power cable (or close the main discon-

nect switch) to supply power.

F. Connections to Three Phase Input Power

WARNING

Disconnect input power from the power supply

and input cable before attempting this procedure.

These instructions are for changing the input power and or

cable on the 208/230, 400, 460 VAC Power Supply to Three -

Phase input power.

1. Remove the Power Supply cover.

See "A. Cover Removal".

2. Disconnect the original input power cable from the

main input contactor and the chassis ground connec-

tion.

3. Loosen the through - hole protector on the back panel

of the power supply. Pull the original power cable out

of the power supply.

4. Using a customer supplied four - conductor input

power cable for the voltage desired, strip back the

insulation on the individual wires.

5. Pass the cable being used through the access opening

in the back panel of the power supply. Refer to Section

2 for power cable specifications.

CAUTION

The primary power source and power cable must

conform to local electrical code and the recom-

mended circuit protection and wiring requirements

(refer to table in Section 2).

6. Connect the wires as follows.

• Wires to L1, L2 and L3 input. It does not matter

what order these wires are attached. See previous

illustration and on label in the power supply.

• Green / Yellow wire to Ground.

7. With a little slack in the wires, tighten the through - hole

protector to secure the power cable.

8. Reinstall the Power Supply cover.

See "B. Cover Installation".

9. Connect the opposite end of individual wires to a cus-

tomer supplied plug or main disconnect.

10. Connect the input power cable (or close the main discon-

nect switch) to supply power.

3.06 Gas Connections

Connecting Gas Supply to Unit

The connection is the same for compressed air or high pressure

cylinders. Refer to the following subsections if an optional air

line filter is to be installed.

1. Connect the air line to the inlet port. The illustration

shows typical fittings as an example.

NOTE

For a secure seal, apply thread sealant to the fitting

threads, according to manufacturer's instructions.

Do not use Teflon tape as a thread sealer, as small

particles of the tape may break off and block the

small air passages in the torch.

Advertising