CUTMASTER A80
OPERATION
Manual 0-4985
4T-24
Aluminum
80A
Air Plasma / Air Shield
Deflector
Standard Shield Cup
Maximum Life Shield Cup
Tip
Starter Cartridge
Heavy Duty Starter
Cartridge
Electrode
9-8243
9-8218
9-8237
9-8211
9-8213
9-8277
9-8232
Material
Thickness
Gas Pressure
(Air)
Arc Voltage Torch Working
Height
Travel Speed Initial Piercing
Height
Pierce Delay
Kerf Width
@ Rec. Speed
(GA) (in)
inch
PSI
(torch lead length)
Volts
(in)
(ipm)
(in)
(sec)
(in)
16
0.064
85 (25')
90 (50')
116
0.25
350
0.25
0.00
0.10
11
0.120
120
0.25
280
0.25
0.10
0.10
3/16
0.188
124
0.25
180
0.25
0.20
0.10
1/4
0.250
130
0.25
110
0.25
0.30
0.09
3/8
0.375
136
0.25
55
0.25
0.40
0.11
1/2
0.500
139
0.25
38
0.25
0.60
0.11
5/8
0.625
136
0.19
26
0.25
0.75
0.10
3/4
0.750
150
0.19
14
Edge Start
0.12
7/8
0.875
153
0.19
10
Edge Start
0.11