Cutmaster a80, Aluminum 80a air plasma / air shield – Tweco A80 CutMaster User Manual

Page 58

Advertising
background image

CUTMASTER A80

OPERATION

Manual 0-4985

4T-24

Aluminum
80A
Air Plasma / Air Shield

Deflector

Standard Shield Cup

Maximum Life Shield Cup

Tip

Starter Cartridge

Heavy Duty Starter

Cartridge

Electrode

9-8243

9-8218

9-8237

9-8211

9-8213

9-8277

9-8232

Material

Thickness

Gas Pressure

(Air)

Arc Voltage Torch Working

Height

Travel Speed Initial Piercing

Height

Pierce Delay

Kerf Width

@ Rec. Speed

(GA) (in)

inch

PSI

(torch lead length)

Volts

(in)

(ipm)

(in)

(sec)

(in)

16

0.064

85 (25')

90 (50')

116

0.25

350

0.25

0.00

0.10

11

0.120

120

0.25

280

0.25

0.10

0.10

3/16

0.188

124

0.25

180

0.25

0.20

0.10

1/4

0.250

130

0.25

110

0.25

0.30

0.09

3/8

0.375

136

0.25

55

0.25

0.40

0.11

1/2

0.500

139

0.25

38

0.25

0.60

0.11

5/8

0.625

136

0.19

26

0.25

0.75

0.10

3/4

0.750

150

0.19

14

Edge Start

0.12

7/8

0.875

153

0.19

10

Edge Start

0.11

Advertising