19 torch valve installation, Torch valve installation -31, Ultra-cut 200 xt – Tweco 200 XT Ultra-Cut Plasma Cutting System User Manual
Page 55
ULTRA-CUT 200 XT
Manual 0-5273
INSTALLATION
3-31
3.19 Torch Valve Installation
General Information
This assembly mounts as close as possible to the torch head. It accepts preflow, plasma, and shield gases from the
Gas Control Module and supplies these gases to the Torch.
Mounting
1.450”
36.83 mm
4.450”
113.03 mm
.261” Dia.
6.63 mm
Art # A-07648
1. Mount the Valve Kit as close as possible to the Torch. The valve kit can be mounted in any convenient posi-
tion, provided the outlet side (with two fittings) is closer to the torch than the inlet side (with three fittings and
a control cable connector).
2. Connect the Valve Kit outlets to the torch leads as shown. (XTL shown)
Art # A-07645
Do not remove brass plugs
Front and side
Right-hand Thread:
To Torch Shield Gas fitting
Left-hand Thread:
To Torch Plasma Gas fitting
Outlet Side