Ultra-cut 200 xt – Tweco 200 XT Ultra-Cut Plasma Cutting System User Manual

Page 59

Advertising
background image

ULTRA-CUT 200 XT

Manual 0-5273

INSTALLATION

3-35

5. Use the cartridge tool to hold the cartridge assembly, while turning the shield cup (and shield retainer for

200 Amp parts) onto the cartridge assembly. For 300 Amp parts turn the shield retainer onto the shield cup

now. When this group is fully assembled, the shield should protrude from the front of the shield cup or

shield retainer. Without this protrusion the shield cup is not properly tightened onto the cartridge assembly.

6. Take the cartridge tool off the cartridge. Fit the cartridge assembly onto the torch head. The Speed Lok

ring should click into place and the cartridge assembly should touch the large O-ring on the torch body.

Torch Head O-Ring

Torch Head

Art # A-08300_AB

0.063 - 0.083"

(1.6 - 2.1 mm)

Protrusion

Installing Assembled Cartridge Onto Torch Head

7. Slide the ohmic clip over the shield cup if using ohmic torch height sensing.

8. Connect the wire lead from the height finder to the ohmic clip if using ohmic torch height sensing.

Ohmic Clip

Art # A-03393_AB

NOTE

Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the

ohmic sensing circuit.