Ultra-cut 200 xt, Gcm 2010 gas control module: controls & indicators, Mode selection switch mode – Tweco 200 XT Ultra-Cut Plasma Cutting System User Manual

Page 71: Gcm 2010

Advertising
background image

ULTRA-CUT 200 XT

Manual 0-5273

OPERATION

4-7

GCM 2010 Gas Control Module: Controls & Indicators

1. MODE Selection Switch

MODE

RUN

SET PREFLOW

SET PLASMA

& SHIELD

TEST

PREFLOW

H

2

O

MIST

PLASMA

SHIELD

PRESSURE

PLASMA

POWER SUPPLY

GAS

FLOW

High Precision

Plasma Cutting System

ENABLE

DISABLE

GAS

MODE

RUN

SET PREFLOW

SET PLASMA

& SHIELD

TEST

O2 - AIR

O2 - O2

H35 -N

2

F5 - N

2

AIR - AIR

N

2 -

H

2

O

N

2 -

N

2

Art # A-04765_AB

9

9

GCM

2010

• Normally in the RUN position during torch operation.
• In the SET PREFLOW position, Preflow or Piloting gas (Air or N

2

) flows to the torch allowing the operator to

adjust pressure. Gas automatically shuts off after 2 minutes if left in the SET PREFLOW position.

• In the SET PLASMA & SHIELD position, selected cutting gases, Plasma & Shield, flow to the torch to allow

operator to set the pressure (regulator & gauge) and flow (knob at top of flowmeter). Gases automatically

shut off after 2 minutes if left in the SET PLASMA & SHIELD position. GCM 2010 gas control revision AG or

later includes inlet pressure sensors. In SET PLASMA & SHIELD position the LCD display shows alternately

the plasma an shield inlet pressure. If either gas pressure is outside the acceptable range, the display shows

“PSI low (or high), the actual pressure and the limit it is below (or above).

• In the TEST position , selected cutting gasses, Plasma & Shield, also flow to the torch. The Plasma outlet pres-

sure (pressure going to the torch), is displayed.

• For GCM 2010 gas control revision AG or later the Mode Selection Switch includes a hidden function used at

initial setup to configure the gas control for the gas lead length. See Sequence of Operation, initial setup.