ULTRA-CUT 400 XT

3-10

INSTALLATION

Manual 0-5275

COOLANT

RETURN SUPPLY

Coolant Connections

RED

GREEN

To HE-400 Heat Exchanger

Art # A-11992

USER INPUT

HEIGHT CONTROL

F1 - 8A SB 230 VAC

F2 - 8A SB 230 VAC

CB4 - 5A 120 VAC

CB3 - 5A 24 VAC

CB2 - 5A 120 VAC

J55 - GCM

J15 - CNC

J59 - RAS

J70 - HE

J54 - TSC /COMM

3.10 Connect Cables for CNC, Remote Arc Starter, GCM and HE 400

1. Connect one end of each cable to the power supply.

2. Connect the other end of the CNC cable to the CNC device

.

3. The CNC cable shield must be attached to ground at the CNC end.