3.17 HE400 COOLER

Used in series with the existing cooling system of the Ultra-Cut XT™ series power supplies, the HE400 Cooler provides additional

cooling when ambient temperatures exceed the units rated temperature. The HE400 fan is thermally controlled to operate whenever

the Ultra-Cut fan and pump is on and the coolant temperature is above a predetermined level. It may come on anytime while the

main pump is operating.

!

WARNING

Do not disassemble the Cooler with the power applied or the coolant flowing. Dangerous 220 AC voltages and high

pressure liquid are present.

Locate the Cooler so that there is adequate ventilation in front of and behind the unit and do not place or stack anything on top

of the unit.

2’ (0.6 m)

2’ (0.6 m)

3”

76 mm

3”

76 mm

Art # A-09623

NOTE

Ensure the four coolant lines described below are connected and leak free before connecting power to J71.