3-34

INSTALLATION

Manual 0-5275

3.19 Torch Valve Installation

General Information

This assembly mounts as close as possible to the torch head. It accepts preflow, plasma, and shield gases from the Gas Control

Module and supplies these gases to the Torch.

Mounting

1.450”

36.83 mm

4.450”

113.03 mm

.261” Dia.

6.63 mm

Art # A-07648

1. Mount the Valve Kit as close as possible to the Torch. The valve kit can be mounted in any convenient position, provided the

outlet side (with two fittings) is closer to the torch than the inlet side (with three fittings and a control cable connector).

2. Connect the Valve Kit outlets to the torch leads as shown.

Art # A-07645

Do not remove brass plugs

Front and side

Right-hand Thread:

To Torch Shield Gas fitting

Left-hand Thread:

To Torch Plasma Gas fitting

Outlet Side