ULTRA-CUT 400 XT

3-40

INSTALLATION

Manual 0-5275

3.22 Voltage Divider for iHC Torch Height Control

For best plasma cutting performance it is necessary to maintain a constant height (standoff) above the metal while cutting. Cutting

tables use a Torch Height Control (THC), also called a Z axis control, most of which use feedback from the arc voltage to control

the height. Several of these, including the iHC, part of the Victor Technologies XT CNC Controller, come with a Voltage Divider

Printed Circuit Board that has to be installed inside the plasma power supply to divide the high arc voltage down to lower levels

for use with control circuits.

There is a space for mounting the V-D Board located on the upper portion of an internal vertical panel near the rear of the power

supply. Predrilled holes for mounting the iHT V-D board as well as another popular height control are provided.

CAUTION

If using another board that doesn’t align with the existing holes, remove the panel if possible before drilling. If not

possible then every precaution must be taken to keep metal filings from being deposited inside the power supply.

Install the V-D Board.

1. Locate the V-D Board which should be with the iCNC.
2. Inside the Power Supply, locate and remove the mounting panel’s 2 screws and panel.
3. Install the V-D board standoffs and the V-D Board from the XT iCNC then reattach the panel with the 2 screws, securing

the V-D board in place. If using another V-D Board, follow the instructions provided mounting it in this same location.

Space for V-D Board

Ohmic clip cable port

V-D Board connection

V-D Board installed

Art # A-12079

V-D Board shown with optional wire harness for iHC controller

Control Cable.

The iHC board can be supplied with a wire harness and connector (shown in previous image), to be installed in the rear panel hole

labeled “Height Control” . The connector mates with a cable from the iHC. For other height control V-D boards a strain relief can

be installed in this hole for those cables. Refer to Appendix for wiring diagram.

USER INPUT

HEIGHT CONTROL

F1 - 8A SB 230 VAC

F2 - 8A SB 230 VAC

CB4 - 5A 120 VAC

CB3 - 5A 24 VAC

CB2 - 5A 120 VAC

J55 - GCM

J15 - CNC

J59 - RAS

J70 - HE

J54 - TSC /COMM

Ohmic clip cable port

V-D Board connection

Art # A-12080