Section 4: operation, 01 power supply control panel, Section 4: operation -1 – Tweco 400 XT Ultra-Cut Plasma Cutting System User Manual

Page 65: Power supply control panel -1, Ultra-cut 400 xt

Advertising
background image

ULTRA-CUT 400 XT

Manual 0-5275

OPERATION

4-1

SECTION 4: OPERATION

4.01 Power Supply Control Panel

Art # A-11541_AB

AC Indicator

Temp Indicator

Gas Indicator

DC Indicator

A/

Status Indicator

A/

AC Power Lamp

Indicates unit has passed the input power tests and AC power is being supplied to the inverter modules via the input contactor

when the ON/OFF switch is in ON position.

TEMP Lamp: Normally OFF. Lamp will come ON when the internal temperature sensors detect temperatures above normal

limits. Let the unit cool before continuing operation.

GAS Lamp: Flashing during start up gas purge/pump priming, then steady whenever gas is flowing. Indicates adequate gas

pressure and coolant flow for operation.

DC Lamp: Indicates the power supply is generating output DC voltage.

A/

Status Indicator: Shows CCM code version on start up followed by the Current Control setting and system status.

Refer to Section 4.07 and Status Code Section for details.

Rear Panel AC Power Lamp

Indicates AC power is present inside the unit

Advertising